20-case baseline
Closed-loop completion · estimated
- All trajectories
- 1,688
- Equivalent scanning time
- ≈ 28.1 h
- Trajectory success
- 55.8%
- Generated fine frames
- 0.197M
- Supervised action targets
- 0.150M
Anatomy-grounded ultrasound world models
Anatomy-Grounded Ultrasound World Models
for Wide-Range Scanning
A persistent anatomical world turns probe actions into ultrasound observations, enabling controllable scanning, scalable demonstrations and repeatable policy evaluation.
Ultrasound is an active sensing problem. A small movement of the probe changes the visible anatomy, and a wide sweep may revisit the same structures from a different acoustic window. A useful scanning environment must connect those observations to one persistent anatomy.
SonoAtlasWorld separates the anatomical state from the image generator. A 3D label volume supplies pose-dependent anatomy and visibility conditions; a causal video model learns ultrasound appearance and temporal continuity from clinical videos.
The study uses an 82,158-clip clinical ultrasound corpus with patient-disjoint splits, and 493 anatomical assets split into 453 training and 40 held-out volumes.
Anatomy as state. A fixed 3D asset anchors the scan, so different paths query the same underlying anatomy.
Probe actions as an interface. Translation and rotation update the probe pose, which determines the anatomical cross-section and acoustic visibility.
Causal observations. Generated history supplies temporal context, supporting interactive scanning and revisits over long rollouts.
Explore a single anatomical world through direct probe control and a goal-conditioned navigation policy.
The navigation policy predicts probe-motion chunks from recent observations and context. New actions produce new ultrasound observations until the target-plane detector reports acquisition.
Console recordings run at their original timing; the controls can change playback speed. Manual inputs are scripted demonstrations. These clips illustrate the interface rather than a new human study or aggregate success benchmark.
Starting from the same initial observation, different probe actions should reveal different, spatially related views. Sliding, fanning and wide scanning query the persistent anatomical state along distinct trajectories.
The three observations in each set are generated for different action sequences from a shared prefix. Use the timeline to inspect corresponding frames.
Anatomical state alone is not the visible image. Ribs, cartilage, contact loss and gas change what the ultrasound beam can reveal. The sampler supplies distinct visibility conditions so the generator can respond as the probe moves.
Vascular appearance changes through the scan.
Anatomical structures enter and leave the imaging plane.
Bone-related dropout changes the visible acoustic window.
Gas is represented by a distinct shadow condition.
Independent selected scan sequences from the paper's scan-event examples; the panels are not one synchronized anatomical scene.
A persistent CT-derived 3D label volume represents anatomy. Probe actions update the pose and restore skin contact. The sampler extracts anatomy and acoustic visibility at that pose, and the causal generator produces the next ultrasound block using the condition and generated history.
The anatomical asset remains fixed throughout the scan. It anchors revisits and different probe trajectories to the same underlying spatial structure.
The generator receives sampled 2D anatomy and visibility conditions rather than directly processing the full 3D volume. The anatomical asset and the observation history serve different roles.
Adapt a video prior to clinical ultrasound and add an anatomical conditioning branch.
Convert generation into a block-causal process that can respond to new probe actions.
Train with generated history to reduce accumulated drift beyond short training windows.
Returning to the same pose after many scan cycles tests more than local video smoothness. It exposes accumulated appearance drift while holding the anatomical target fixed.
At cycle 40: 0.594 → 0.172.
Short-rollout model versus long-rollout-aligned model.
Single H100 benchmark. Approximately 250 ms steady-state pose-to-first-frame latency; output is generated in blocks.
Repeated-cycle stress test: 36 cases × 3 seeds, 40 cycles, recent-history / no-sink setting. S and L denote the short-rollout and long-rollout-aligned variants. Throughput and latency are separate measurements from the inference benchmark.
Image similarity alone can reward a model that hardly changes. We reconstruct generated structures at known probe poses and compare them with the 3D reference. The Action-Following Index (AFI) measures normalized reconstruction gain over a static-prefix baseline.
Anatomical recovery is evaluated against the reference volume. AFI is a normalized index, not clinical accuracy.
| Method | Training | Liver Dice ↑ | Liver AFI ↑ | Macro Dice ↑ | Macro AFI ↑ | Vascular mm ↓ | Warp error ↓ |
|---|---|---|---|---|---|---|---|
| No control | |||||||
| Prefix only | — | .670 | 0 | .219 | 0 | 3.62 | — |
| Action- or geometry-conditioned models | |||||||
| SonoWorld† | Real | .662 | .107 | .220 | .032 | 3.33 | 2.39 |
| SonoWorld† | Sim | .605 | .084 | .208 | .031 | 3.66 | 2.50 |
| UltraWorld† | Real | .667 | .117 | .224 | .038 | 3.40 | 2.52 |
| UltraWorld† | Sim | .518 | .041 | .171 | .020 | 3.42 | 2.44 |
| Frame-conditioned rendering | |||||||
| SonoGym† | Real | .811 | .434 | .301 | .200 | 2.93 | 4.91 |
| Teacher and causal variants | |||||||
| Bidirectional teacher | Real | .838 | .472 | .352 | .250 | 2.10 | 2.58 |
| Framewise variant | Real | .815 | .443 | .352 | .258 | 1.83 | 2.86 |
| SonoAtlasWorld | Real | .813 | .428 | .356 | .262 | 1.75 | 1.90 |
40 held-out 3D volumes. † Adapted re-implementations. Vascular distance is conditional on detection within 10 mm. Warping error uses 8-bit gray levels. Teacher and framewise results are included to make the quality–continuity trade-off visible.
Five methods share the same ultrasound prefix and probe trajectory. Play them together to inspect how anatomy and appearance evolve.
Prefix-only baseline
Adapted model · real-ultrasound training
Adapted model · real-ultrasound training
Adapted model · real-ultrasound training
Anatomy-grounded generation
Prefix is the prefix-only baseline. SonoWorld, UltraWorld and SonoGym are adapted re-implementations trained on real ultrasound; SonoAtlasWorld uses the same selected benchmark trajectory. The videos use synchronized playback for direct qualitative inspection.
The world model generates observations along offline expert trajectories. A goal-conditioned diffusion policy learns probe actions from those demonstrations, then interacts with the frozen world model on unseen anatomies.
Increasing the training set from 20 to 453 anatomical volumes expands demonstrations from 1,688 to 39,246 trajectories. The policy architecture and training budget are held fixed.
Goal-plane success rises from 48.2% to 81.2% across the runs displayed in the paper. Each policy is frozen during evaluation; observations respond to its newly predicted actions.
Paper protocol: 112 episodes on 36 held-out cases per configuration, GI score ≥ 0.6 from frame 5 onward, with a phase-triggered fine-scan window. This is trajectory-level acquisition in simulation. Displayed small-data runs are selected individual seeds, not seed averages, and are sensitive to training-seed variability.
Broader anatomy, more starting poses and recovery trajectories expand the experience available to a scanning policy.
20-case baseline
Closed-loop completion · estimated
453-case deployed DP
Closed-loop completion · reported
Next Scale?
What if?
Linear data-volume projection; policy success remains to be evaluated.
Estimates: ~1 min/trajectory; in clinical scan this might be even longer. The 20K-case projection assumes the current density of 39,246 / 453 ≈ 86.6 trajectories per case. Action targets include overlapping prediction windows.
The manuscript describes the anatomical assets, world-model training, evaluation protocols and downstream policy experiments.
Learning robotic ultrasound policies requires interactive environments for scalable data generation and repeatable evaluation, while exploration on real patients is limited by acquisition costs and safety constraints. Generative world models offer an alternative, but image history and probe actions alone do not ensure anatomical consistency across wide-range scans and changing acoustic windows. We introduce SonoAtlasWorld, an ultrasound world model built on anatomy as state. A persistent 3D anatomical asset extracted from computed tomography anchors each scan to a specific anatomy. Probe actions determine anatomical and acoustic visibility conditions for a causal ultrasound generator trained on clinical videos. Our three-stage pipeline combines anatomy-conditioned pretraining, causal conversion and long-rollout alignment. On 40 held-out 3D volumes, reconstruction-based evaluation measures anatomical action following beyond image similarity. Long-rollout alignment reduces brightness drift by 3.46× after 40 repeated scan cycles. SonoAtlasWorld also generates offline policy-training demonstrations and supports anatomically grounded closed-loop evaluation on unseen anatomies in simulation.