SonoAtlasWorld

Anatomy-grounded ultrasound world models

SonoAtlasWorld

Anatomy-Grounded Ultrasound World Models
for Wide-Range Scanning

A persistent anatomical world turns probe actions into ultrasound observations, enabling controllable scanning, scalable demonstrations and repeatable policy evaluation.

0:00 / 0:00
Interactive probe-controlled scanningGenerated ultrasound · recorded console demonstration
82,158Clinical ultrasound clips
4933D anatomical assets
81.2 FPSPose-to-US throughput
3.46×Lower cycle-40 brightness drift

Overview

A visual research tour

Ultrasound is an active sensing problem. A small movement of the probe changes the visible anatomy, and a wide sweep may revisit the same structures from a different acoustic window. A useful scanning environment must connect those observations to one persistent anatomy.

SonoAtlasWorld separates the anatomical state from the image generator. A 3D label volume supplies pose-dependent anatomy and visibility conditions; a causal video model learns ultrasound appearance and temporal continuity from clinical videos.

The study uses an 82,158-clip clinical ultrasound corpus with patient-disjoint splits, and 493 anatomical assets split into 453 training and 40 held-out volumes.

  • Anatomy as state. A fixed 3D asset anchors the scan, so different paths query the same underlying anatomy.

  • Probe actions as an interface. Translation and rotation update the probe pose, which determines the anatomical cross-section and acoustic visibility.

  • Causal observations. Generated history supplies temporal context, supporting interactive scanning and revisits over long rollouts.

Interactive Scanning

Explore a single anatomical world through direct probe control and a goal-conditioned navigation policy.

SHH to FHH · goal-conditioned navigationBDMAP_00000745 · uC7-1
0:00 / 0:00

The navigation policy predicts probe-motion chunks from recent observations and context. New actions produce new ultrasound observations until the target-plane detector reports acquisition.

Console recordings run at their original timing; the controls can change playback speed. Manual inputs are scripted demonstrations. These clips illustrate the interface rather than a new human study or aggregate success benchmark.

Different Actions, Shared Anatomy

Starting from the same initial observation, different probe actions should reveal different, spatially related views. Sliding, fanning and wide scanning query the persistent anatomical state along distinct trajectories.

Shared prefix within each set
Slidetranslation
Fanangular sweep
Wide scanlarger excursion
0:00 / 0:06

The three observations in each set are generated for different action sequences from a shared prefix. Use the timeline to inspect corresponding frames.

Changing Acoustic Windows

Anatomical state alone is not the visible image. Ribs, cartilage, contact loss and gas change what the ultrasound beam can reveal. The sampler supplies distinct visibility conditions so the generator can respond as the probe moves.

Portal-vein long axis

0:00 / 0:00

Vascular appearance changes through the scan.

Hepatic-vein view

0:00 / 0:00

Anatomical structures enter and leave the imaging plane.

Rib-induced occlusion

0:00 / 0:00

Bone-related dropout changes the visible acoustic window.

Gas shadow

0:00 / 0:00

Gas is represented by a distinct shadow condition.

Independent selected scan sequences from the paper's scan-event examples; the panels are not one synchronized anatomical scene.

Anatomy as State

A persistent CT-derived 3D label volume represents anatomy. Probe actions update the pose and restore skin contact. The sampler extracts anatomy and acoustic visibility at that pose, and the causal generator produces the next ultrasound block using the condition and generated history.

The anatomical asset remains fixed throughout the scan. It anchors revisits and different probe trajectories to the same underlying spatial structure.

Select image to enlarge

The generator receives sampled 2D anatomy and visibility conditions rather than directly processing the full 3D volume. The anatomical asset and the observation history serve different roles.

Anatomy-conditioned pretraining

Adapt a video prior to clinical ultrasound and add an anatomical conditioning branch.

Causal few-step distillation

Convert generation into a block-causal process that can respond to new probe actions.

Long-rollout alignment

Train with generated history to reduce accumulated drift beyond short training windows.

Sustained Scanning

Returning to the same pose after many scan cycles tests more than local video smoothness. It exposes accumulated appearance drift while holding the anatomical target fixed.

Select image to enlarge
3.46×

Lower brightness drift

At cycle 40: 0.594 → 0.172.
Short-rollout model versus long-rollout-aligned model.

81.2 FPS

Pose-to-ultrasound throughput

Single H100 benchmark. Approximately 250 ms steady-state pose-to-first-frame latency; output is generated in blocks.

Repeated-cycle stress test: 36 cases × 3 seeds, 40 cycles, recent-history / no-sink setting. S and L denote the short-rollout and long-rollout-aligned variants. Throughput and latency are separate measurements from the inference benchmark.

Does Anatomy Follow Probe Actions?

Image similarity alone can reward a model that hardly changes. We reconstruct generated structures at known probe poses and compare them with the 3D reference. The Action-Following Index (AFI) measures normalized reconstruction gain over a static-prefix baseline.

Select image to enlarge

Anatomical recovery is evaluated against the reference volume. AFI is a normalized index, not clinical accuracy.

MethodTrainingLiver Dice ↑Liver AFI ↑Macro Dice ↑Macro AFI ↑Vascular mm ↓Warp error ↓
No control
Prefix only—.6700.21903.62—
Action- or geometry-conditioned models
SonoWorld†Real.662.107.220.0323.332.39
SonoWorld†Sim.605.084.208.0313.662.50
UltraWorld†Real.667.117.224.0383.402.52
UltraWorld†Sim.518.041.171.0203.422.44
Frame-conditioned rendering
SonoGym†Real.811.434.301.2002.934.91
Teacher and causal variants
Bidirectional teacherReal.838.472.352.2502.102.58
Framewise variantReal.815.443.352.2581.832.86
SonoAtlasWorldReal.813.428.356.2621.751.90

40 held-out 3D volumes. † Adapted re-implementations. Vascular distance is conditional on detection within 10 mm. Warping error uses 8-bit gray levels. Teacher and framewise results are included to make the quality–continuity trade-off visible.

Matched-method qualitative comparison

Five methods share the same ultrasound prefix and probe trajectory. Play them together to inspect how anatomy and appearance evolve.

0:00 / 0:06
PrefixShared trajectory

Prefix-only baseline

SonoWorldShared trajectory

Adapted model · real-ultrasound training

UltraWorldShared trajectory

Adapted model · real-ultrasound training

SonoGymShared trajectory

Adapted model · real-ultrasound training

SonoAtlasWorldShared trajectory

Anatomy-grounded generation

Prefix is the prefix-only baseline. SonoWorld, UltraWorld and SonoGym are adapted re-implementations trained on real ultrasound; SonoAtlasWorld uses the same selected benchmark trajectory. The videos use synchronized playback for direct qualitative inspection.

From Scanning Experience to Policy Learning

The world model generates observations along offline expert trajectories. A goal-conditioned diffusion policy learns probe actions from those demonstrations, then interacts with the frozen world model on unseen anatomies.

Select image to enlarge

Scale the training experience

Increasing the training set from 20 to 453 anatomical volumes expands demonstrations from 1,688 to 39,246 trajectories. The policy architecture and training budget are held fixed.

Measure closed-loop acquisition

Goal-plane success rises from 48.2% to 81.2% across the runs displayed in the paper. Each policy is frozen during evaluation; observations respond to its newly predicted actions.

Paper protocol: 112 episodes on 36 held-out cases per configuration, GI score ≥ 0.6 from frame 5 onward, with a phase-triggered fine-scan window. This is trajectory-level acquisition in simulation. Displayed small-data runs are selected individual seeds, not seed averages, and are sensitive to training-seed variability.

Ultrasound AI Needs More Scanning Experience

Broader anatomy, more starting poses and recovery trajectories expand the experience available to a scanning policy.

20-case baseline

9.7%

Closed-loop completion · estimated

All trajectories
1,688
Equivalent scanning time
≈ 28.1 h
Trajectory success
55.8%
Generated fine frames
0.197M
Supervised action targets
0.150M

453-case deployed DP

61%

Closed-loop completion · reported

All trajectories
39,246
Equivalent scanning time
≈ 654.1 h
Trajectory success
85.7%
Generated fine frames
1.781M
Supervised action targets
1.051M

Next Scale?

20Kcases

What if?

All trajectories
≈ 1,732,715
Equivalent scanning time
≈ 28,879 h

Linear data-volume projection; policy success remains to be evaluated.

Estimates: ~1 min/trajectory; in clinical scan this might be even longer. The 20K-case projection assumes the current density of 39,246 / 453 ≈ 86.6 trajectories per case. Action targets include overlapping prediction windows.

Paper & Resources

The manuscript describes the anatomical assets, world-model training, evaluation protocols and downstream policy experiments.

Research summary

Learning robotic ultrasound policies requires interactive environments for scalable data generation and repeatable evaluation, while exploration on real patients is limited by acquisition costs and safety constraints. Generative world models offer an alternative, but image history and probe actions alone do not ensure anatomical consistency across wide-range scans and changing acoustic windows. We introduce SonoAtlasWorld, an ultrasound world model built on anatomy as state. A persistent 3D anatomical asset extracted from computed tomography anchors each scan to a specific anatomy. Probe actions determine anatomical and acoustic visibility conditions for a causal ultrasound generator trained on clinical videos. Our three-stage pipeline combines anatomy-conditioned pretraining, causal conversion and long-rollout alignment. On 40 held-out 3D volumes, reconstruction-based evaluation measures anatomical action following beyond image similarity. Long-rollout alignment reduces brightness drift by 3.46× after 40 repeated scan cycles. SonoAtlasWorld also generates offline policy-training demonstrations and supports anatomically grounded closed-loop evaluation on unseen anatomies in simulation.

Scope: the experiments establish controllable generation, anatomical evaluation and policy learning within simulation. Physical robotic scanning, tissue deformation and transfer to real patients require further validation.